AEMC 2137.57 PEL 105 Power and Energy Loggers

VISIT THE PEL SERIES WEBSITE: www.PEL100.us

Features

  • Waterproof IP67 rated including the current sensors
  • 5 voltage and 4 current measurement inputs
  • Measures volts, amps, watts, VARs, kWh, power factor and harmonics out to the 50th
  • Track energy costs including time of use
  • Wi-Fi, Bluetooth Class 1, USB, LAN and Ethernet communication built in
  • Powered from phase inputs up to 1000VAC or from a wall receptacle
  • User selectable storage rates and demand intervals
  • Pole mountable
  • Can be configured directly from the front panel, through the DataView ® control panel or the free Android App
  • Satisfies the recommendations of NEC 220.87
  • Minimal programming required
  • Automatic recognition of the connected current sensors/probes

Applications

  • Measures efficiency and finds areas for potential savings
  • Assign energy costs to departments or operations
  • Track peak demand periods and find opportunities for surcharge reductions
  • Determine present capacity and circumvent unnecessary electrical expansion costs
  • Verify the reliability and operation of electrical machinery
  • Improve response time to solve power related problems
  • Track energy availability and reliability of supply
  • Baseline studies for system upgrades in high-rise and office buildings

Statistics

GENERAL SAMPLING FREQUENCY:
128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz)
GENERAL DATA STORAGE RATE:
samples per cycle; 50/60Hz (16 samples/cycle 400Hz) Data Storage Rate 1 per second (200ms also available on PEL 105)
GENERAL DEMAND PERIOD STORAGE RATE:
User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes)
GENERAL RECORDED PARAMETERS (SINGLE- AND POLY-PHASE):
V, I, W, VA, var, PF, Tan, Wh, VAh, varh, THD (V and I), Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF
GENERAL EVENT LOG:
Tracks and records status changes and error messages along with recorded data
GENERAL FRONT PANEL INDICATOR LEDS:
Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status
GENERAL STORAGE CAPACITY:
SD card included / SD cards up to 32 GB formatted FAT32 are supported
INPUTS VOLTAGE:
PEL 102/103 – 3 input channels; PEL 105 – 4 input channels via 4mm safety banana jacks
INPUTS CURRENT:
PEL 102/103 - 3 current input channels ; PEL 105 – 4 input channels via custom 4 pin jacks that accept AEMC® probes and sensors
ELECTRICAL:
.
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* 50/60HZ:
42.5 to 69Hz, ±0.1Hz
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* SINGLE-PHASE RMS VOLTAGES:
10 to 1000Vrms, 0.1V/±0.2% Rdg ± 0.2V
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* PHASE-TO-PHASE RMS VOLTAGES:
17 to 1000Vrms, 0.1 to 1V/±0.2% Rdg ± 0.4V
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* 400HZ:
340 to 460Hz
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* SINGLE-PHASE RMS VOLTAGES:
10 to 600Vrms, 0.1V/±1% Rdg ± 1V
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* PHASE-TO-PHASE RMS VOLTAGES:
17 to 1200Vrms, 0.1 to 1V/±1% Rdg ± 1V
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* DC:
10 to 1000V, 0.1V/±1% Rdg ± 3V (typical)
VOLTAGE MEASUREMENT/RESOLUTION/ACCURACY* PT RATIOS:
1% Rdg ± 3V (ty
CURRENT MEASUREMENT:
A193***, A196***
CURRENT MEASUREMENT NOMINAL RANGE FOR CURRENT PROBES SUPPLIED WITH KIT. SEE CHART ON PAGES 26 AND 27 FOR OTHER PROBES:
200mA to 3000Arms, 200mA to 10,000A
CURRENT MEASUREMENT CT RATIOS:
Programmable from 1:1 to 25,000:1 (probe dependent)
POWER MEASUREMENTS ACTIVE POWER (P)*:
0.001W, ±0.5% Rdg ± 0.005% Pnom
POWER MEASUREMENTS REACTIVE POWER (Q)*:
0.001var, m Reactive Power (Q)* -2 to 2Gvar 0.001var ±
POWER MEASUREMENTS APPARENT POWER (S)*:
0.001VA, ±0.5% Rdg ± 0.005% Snom
POWER MEASUREMENTS POWER FACTOR:
0.001, ± 0.05
POWER MEASUREMENTS TANGENT ? (ACTIVE/REACTIVE POWER RATIO):
0.001, ± 0.02
ENERGY MEASUREMENTS ACTIVE ENERGY (EP):
1Wh, ±0.5% Rdg
ENERGY MEASUREMENTS REACTIVE ENERGY (EQ):
1varh, ±2% Rdg
ENERGY MEASUREMENTS APPARENT ENERGY (ES):
1Vah, ±0.5% Rdg
THD:
± 655%
THD INDIVIDUAL HARMONICS:
1 to 50 displayed in percentage; 1 to 7 at 400Hz
THD EXTERNAL SUPPLY:
110V/250V (10%) @ 50/60Hz; 400Hz
THD POWER FROM PHASE MEASUREMENT:
PEL 102/103 requires optional Power Adapter Cat #2137.77; PEL 105 Internal up to 1000Vac
THD BACK-UP POWER SOURCE/CHARGE TIME:
Rechargeable 8.4V NiMH battery pack / Approximately 5 hours
THD BATTERY LIFE:
30 minutes minimum, 60 minutes typical
MECHANICAL COMMUNICATION PORTS:
USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 **/ Wi-Fi (PEL 105 only)
MECHANICAL DIMENSION/WEIGHT:
10.08 x 4.92 x 1.46 (256 x 125 x 37mm) / 2.20lbs (1kg) (PEL 102 & PEL 103)
9.8 X 7.8 X 2.6" (250 X 200 X 67MM) / 8.8LBS (4KG) (PEL 105)":
.
MECHANICAL CASE:
Double insulated, rubber over-molded, polycarbonate UL94 V1 rated
MECHANICAL MOUNTING/SECURITY:
Kensington anti-theft system (PEL 102 & PEL 103) / Embedded magnets on back side, keyhole slot on back side
DISPLAY:
.
DISPLAY DISPLAY TYPE FOR MODEL PEL 103 / PEL 105:
2.63 x 2.16 (67 x 55mm), four line, monochrome, backlit LCD with adjustable brightness and contrast"
ENVIRONMENTAL / SAFETY:
.
ENVIRONMENTAL / SAFETY OPERATING TEMPERATURE/RELATIVE HUMIDITY:
50 to 122F (10 to 50C) / up to 85%
ENVIRONMENTAL / SAFETY STORAGE TEMPERATURE:
-4 to 122F (-20 to 50C) with batteries; -4 to 158F (-20 to 70C without batteries)
ENVIRONMENTAL / SAFETY SAFETY RATING/CE RATING:
Complies with IEC 61010-1:Ed3, and IEC 61010-2-030: Ed1 for 1000V CAT III / 600V CAT IV (PEL 102 & PEL 103) & 1000V CAT IV (PEL 105), Pollution Degree 2 / Yes
ENVIRONMENTAL / SAFETY INDEX OF PROTECTION:
IP54 non operating (PEL 102 & PEL 103) / IP67 with cover closed (PEL 105

 